Solution:
Root Cause: Hardware Protection Latch Caused by Soft Short or Welded Relay
If the power station displays
OVERLOAD or
SHORT when no external devices or cables are plugged in, an internal short circuit condition is detected. This occurs when either an internal AC transfer relay contacts have welded due to an arc, a solid-state discharge MOSFET has suffered thermal breakdown (failing shorted), or a hardware fault bit is permanently latched inside the BMS EEPROM.
Diagnostic Verification:
1Ensure all input cables, DC output adapters, and AC plugs are completely removed.
2Turn on the unit: If the error code appears immediately within 1-2 seconds without activating any output button, the fault is internal.
Step-by-Step Fix:
1Execute Complete System Deep Drain (Capacitance Discharge):
Power off the main unit.Press and hold the Main Power Button along with both AC and DC buttons simultaneously for 60 seconds.Leave the unit completely disconnected and powered off for a full 4 to 6 hours to allow all internal high-voltage electrolytic capacitors to bleed off completely.2Apply Firmware Force-Flash via Companion App (if accessible):
Turn on the unit's Bluetooth/Wi-Fi connection.Open the official vendor companion app (EcoFlow, Bluetti, Anker, Jackery).Navigate to Settings > Firmware Update > Select Force Re-install / Update to rewrite the BMS configuration parameters.3Hardware Inspection (If Out of Warranty):
If error persists, the unit requires authorized service or internal MOSFET/board replacement by a certified technician.Prevention & Long-Term Monitoring:
Avoid switching heavy AC loads on and off rapidly to reduce high-voltage arcing across internal relay contacts.